中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Firetox Flame Retardant Cables 
Flame Retardant Power & Control Cables
Flame Retardant Instrumention Cables
Flame Retardant Data Cables
Flame Retardant Databus Cables
Flame Retardant Coaxial Cables
Flame Retardant Optic Fiber Cables

Flame Retardant Databus Cables

Flame Retardant RS485 Databus Cables

Flame Retardant Data Cables

APPLICATION
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT,
100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper
wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically
protection still maintaining the flexibility of the cable.

STANDARDS
Basic design to EIA/TIA 485

FIRE PERFORMANCE

Flame Retardance (Single Vertical
Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING
60V

CABLE CONSTRUCTION
Multipair RS 485 Overall Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize
crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall screen: Aluminum/polyester tape with tinned copper drain wire.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)

Multipair RS 485 Overall Double Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize
crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall screen: Aluminium/polyester tape+copper wire braid.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH
compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

Multipair RS 485 Individual & Overall screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize
crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Individual Screen: Individual aluminium/polyester tape.
Overall Screen: Copper wire braid.
outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH
compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

Multipair RS 485 Overall Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize
crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall Screen: Copper wire braid.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH
compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -20°C - +90°C
Temperature range during installation (mobile state): -5°C - +60°C
Minimum bending radius: 8 x Overall Diameter

Electrical Properties

Dielectric test

1000 V r.m.s. for 5’ (core-core)

 

1000 V r.m.s. for 5’ (core-screen)

Impedance

120Ω

capacitance

45 nF/km conductor to conductor

 

90 nF/km conductor to shield

CONSTRUCTION PARAMETERS
Multipair RS 485 Overall Screened Databus Cable
RE-02Y(St)H / RE-02YS(St)H

No.of pair x

Nominal Cross Sectional Area

No./Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

 

mm2

No/mm

mm

mm

mm

kg/km

1

0.22

7/0.2

0.55

0.40

4.0

21

2

0.22

7/0.2

0.55

0.40

7.1

42

4

0.22

7/0.2

0.55

0.40

8.3

68

1

0.50

16/0.2

0.55

0.40

4.6

32

2

0.50

16/0.2

0.55

0.40

8.2

68

4

0.50

16/0.2

0.55

0.40

9.8

115

1

0.75

24/0.2

0.55

0.40

5.1

40

2

0.75

24/0.2

0.55

0.40

9.1

84

4

0.75

24/0.2

0.55

0.40

10.9

144

1

1.00

30/0.2

0.55

0.40

5.2

49

2

1.00

30/0.2

0.55

0.40

9.5

105

4

1.00

30/0.2

0.55

0.40

11.2

182

Multipair RS 485 Overall Double Screened Databus Cable
RE-02Y(St)CH / RE-02YS(St)CH

No.of pair x

Nominal
Cross Sectional Area

No./Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

 

mm2

No/mm

mm

mm

mm

kg/km

1

0.22

7/0.2

0.55

0.40

4.5

34

2

0.22

7/0.2

0.55

0.40

7.5

67

4

0.22

7/0.2

0.55

0.40

8.8

97

1

0.50

16/0.2

0.55

0.40

5.1

48

2

0.50

16/0.2

0.55

0.40

8.7

97

4

0.50

16/0.2

0.55

0.40

10.3

150

1

0.75

24/0.2

0.55

0.40

5.6

57

2

0.75

24/0.2

0.55

0.40

9.7

116

4

0.75

24/0.2

0.55

0.40

11.4

182

1

1.00

30/0.2

0.55

0.40

5.7

67

2

1.00

30/0.2

0.55

0.40

10.0

138

4

1.00

30/0.2

0.55

0.40

11.8

222

Multipair RS 485 Individual & Overall screened Databus Cable
RE-02Y(St)H pimf / RE-02YS(St)H pimf

No.of pair x

Nominal
Cross Sectional Area

No./Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

 

mm2

No/mm

mm

mm

mm

kg/km

1

0.22

7/0.2

0.55

0.40

4.4

35

2

0.22

7/0.2

0.55

0.40

7.5

69

4

0.22

7/0.2

0.55

0.40

8.8

106

1

0.50

16/0.2

0.55

0.40

5.0

49

2

0.50

16/0.2

0.55

0.40

8.7

100

4

0.50

16/0.2

0.55

0.40

10.3

159

1

0.75

24/0.2

0.55

0.40

5.5

58

2

0.75

24/0.2

0.55

0.40

9.7

119

4

0.75

24/0.2

0.55

0.40

11.2

174

1

1.00

30/0.2

0.55

0.40

5.6

68

2

1.00

30/0.2

0.55

0.40

10.0

142

4

1.00

30/0.2

0.55

0.40

11.8

234

Multipair RS 485 Overall Screened Databus Cable
RE-02YCH / RE-02YSCH

No.of pair x

Nominal
Cross Sectional Area

No./Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

 

mm2

No/mm

mm

mm

mm

kg/km

1

0.22

7/0.2

0.55

0.40

4.3

31

2

0.22

7/0.2

0.55

0.40

7.3

61

4

0.22

7/0.2

0.55

0.40

8.5

91

1

0.50

16/0.2

0.55

0.40

4.9

44

2

0.50

16/0.2

0.55

0.40

8.5

91

4

0.50

16/0.2

0.55

0.40

10.0

142

1

0.75

24/0.2

0.55

0.40

5.4

53

2

0.75

24/0.2

0.55

0.40

9.5

109

4

0.75

24/0.2

0.55

0.40

11.2

174

1

1.00

30/0.2

0.55

0.40

5.5

63

2

1.00

30/0.2

0.55

0.40

9.8

131

4

1.00

30/0.2

0.55

0.40

11.5

213

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com